The Cen Tech 95670 is a versatile digital multimeter designed for automotive diagnostics and general electrical testing. It features a large LCD display, multiple measurement functions (AC/DC voltage, current, resistance, continuity, diode test, transistor hFE), overload protection, data hold, and auto power-off. Powered by a 9V battery, it includes test leads, a carrying case, and an instruction manual. Below are key sections for safety, features, operation, measurement procedures, maintenance, and troubleshooting.
Key components: Digital LCD display, Function selector dial, Input jacks, Test leads, Data hold button, Transistor test socket.
| Feature | Description |
|---|---|
| Large LCD display | 3½ digit, 2000 count display with backlight |
| Function selector | Rotary switch for selecting measurement modes |
| Input jacks | COM, VΩmA, and 10A for test lead connections |
| Test leads | Red and black insulated leads with probes |
| Data hold | Freezes displayed reading |
| Continuity buzzer | Audible tone for circuit continuity |
| Diode test | Measures forward voltage drop of diodes |
| Transistor hFE | Tests transistor DC current gain |
| Auto power-off | Conserves battery after 15 minutes of inactivity |
| Overload protection | Fused protection for current measurements |
Read all safety information before use. This meter is designed for indoor use.
WARNING! Risk of electric shock. Do not use on circuits exceeding 600V. Use caution when working with high voltage.
Front panel layout and control functions.
CAUTION! Ensure rotary switch is set to correct function before connecting to circuit.
Insert battery and connect test leads.
Tip: Always start with highest range if unknown value, then switch to lower range for better accuracy.
Step-by-step instructions for common measurements.
WARNING! Never connect meter to powered circuit when set to current or resistance mode.
Data Hold: Press HOLD button to freeze reading. Auto Power-Off: Meter turns off after 15 minutes; press any button to wake. Low Battery Indicator: "BAT" appears when battery needs replacement.
Replace 9V battery when low battery indicator appears.
CAUTION! Dispose of old battery properly according to local regulations.
Clean meter with dry cloth only. Store in carrying case when not in use.
CAUTION! Do not expose to extreme temperatures, moisture, or direct sunlight.
Cen Tech 95670 comes with a 1-year limited warranty covering defects in materials and workmanship. Warranty does not cover damage from misuse, accidents, or unauthorized modifications. For warranty service, contact Harbor Freight Tools at 1-800-444-3353 or visit www.harborfreight.com. Keep original receipt as proof of purchase.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead battery | Replace 9V battery. |
| Inaccurate readings | Low battery/wrong range | Replace battery; select proper range. |
| Continuity buzzer not working | High resistance/open circuit | Check circuit continuity; resistance must be < 50Ω. |
| Meter turns off automatically | Auto power-off feature | Press any button to wake; disable by holding HOLD while turning on. |
| Display shows "OL" | Overload/out of range | Select higher range; check circuit voltage/current. |
Reset: Remove battery for 30 seconds, then reinstall.
Service: 1-800-444-3353; www.harborfreight.com